PDU Smart, 0U, 24 x IEC C13, 6x IEC C19 Outlets, 230V, 16A

Mehr Ansichten

PDU Smart, 0U, 24 x IEC C13, 6x IEC C19 Outlets, 230V, 16A
SKU: STV-3531J

PDU Smart, 0U, 24 x IEC C13, 6x IEC C19 Outlets, 230V, 16A (Master)



  • 0U

  • 24 x IEC C13 Outlets

  •   6 x IEX C19 Outlets

  • 230V 16A

  • (Master)

Technisches Datenblatt als PDF herunterladen ›

Downloads


Beschreibung

Produktbeschreibung

PDU Smart, 0U, 24 x IEC C13, 6x IEC C19 Outlets, 230V, 16A

  • 0U
  • 24 x IEC C13 Outlets (Global Rating: ≤ 10A @230V L-N)
  •   6 x IEC C19 Outlets (Global Rating: ≤ 16A @230V L-N)
  • LED amp meter
  • 230V 16A
  • Input IEC 230V/16A 2P+PE 6Hr
  • w- 2 x Temp-Humid Capable
  • Branch Circuit Protection: UL489 Compliant 2-pole, 20A trip circuit breakers, two (2) branch, rating: ≤ 16A, 5 kAIC Interrupt Rating
  • Expansion - Slave Part no. SEV-3531J (Link)

Physical

Dimensions: 60.0in tall x 1.75in wide x 2.25in deep [1524mm x 45mm x 58mm]

Environmental

  • Operating Environment:32°Fto140°F/0°Cto60°C|8%RHto90%RHnon-condensing|6,500ft/2kmelevation Storage Environment:-40°Fto185°F/-40°Cto85°C|8%RHto90%RHnon-condensing|50,000ft/15kmelevation Quiescent / Unloaded Power Draw: < 10W for all configurations

Communications & Security

  • 10/100 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector)
  • Two (2) temperature/humidity sensor inputs (4P4C), Link port (RJ-12) - {also on Link PDU}
  • Web-browser GUI and command-line interface (CLI): HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c and v3 (GET, SET, Traps), IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP

Certifications

Global:

  • TUV T-Mark to EN 60950-1:2006+A11+A1+A12+A2
  • EMC to EN55024 (2010) and EN55032 (2012)
  • CE Compliant
  • RoHS, European Hazardous Materials Directive (Recast) 2011/65/EU WEEE Compliant

Measurement Accuracy

Input Measurement Accuracy:

  • LED Current = ± 10% at 0.1 amp (0.3 - 9.9 amps) and 1 amp (> 9.9 amps) resolution GUI Current = ± 1% at 0.01 amp resolution (above 0.25 amp)
  • Voltage = ± 1% at 0.1 volt resolution (nominal ± 10%)
  • Active Power = ± 1% at 1 watt resolution
  • Apparent Power = ± 1% at 1 volt-amp resolution
  • Power Factor = ± 3% at 0.01 resolution Crest Factor = ± 10% at 0.1 resolution Energy = ± 1% at 0.1 kilowatt-hour resolution

Optional Accessories

  • EMTH-1-1 Combination Temperature/Humidity Probe, 10ft (3m) EMCU-1-1B Environmental Monitor adding:
  • - Two (2) EMTH-1-1 temperature/humidity ports (one probe included) - One (1) EMWS-1-1 water sensor port (probe sold separately)
  • - Four (4) dry contact (NO/NC) monitoring points
  • - One (1) 8-bit analog-to-digital converter (0 to 5VDC)
  • KIT-STEYE-01 or -10 provides access to key metrics through Bluetooth KIT-SUS-01 StartUp StickTM for rapid configurationMounting Brackets - Buttons (KIT-0020) included for tool-less mounting (see diagram)
  • - See the Mounting Bracket Guide for further suggestions
  • - Custom mounting options available. Contact your local Server Technology representative Cable Retention Devices for non-locking cords
  • -EZip
  • - Cable Sleeve

 

Zusatzinformation

Zusatzinformation

Artikelnummer STV-3531J
Produkt Verfügbarkeit Nein
Steckdosen C-13 & C-19 Kaltgeräte
Volt 230 Volt
Phasen einphasig
PDU Typ Smart PDU